Demo site built by Roof Flow Sites
Roof systems

Structural and architectural metal panel

Standing Seam Metal

The longest-lived assembly we install. Higher first cost, near-zero membrane maintenance, and a service life that outlasts most ownership horizons on the buildings we work on.

Composition

24 or 22 gauge steel, or 0.032 aluminum, in concealed-clip standing seam panels over purlins or a solid deck with a high-temperature underlayment.

Thickness options

24 gauge standard, 22 gauge on spans over five feet or high-uplift zones.

Seam method

Mechanically double-locked 180 degree seam, field-seamed with a powered seamer. Clips allow thermal movement along the panel run.

Expected service life

40 to 50 years on the panel, with the coating finish typically the first thing to age.

Specification note

Slope governs. Below a 1:12 pitch we will not warrant a standing seam assembly and will recommend a single-ply or modified bitumen system instead.

Best applications

  • Manufacturing and agricultural buildings with sloped structural decks
  • Retrofit over a failed metal roof using a sub-purlin framing system
  • Long-hold owner-occupied assets where life-cycle cost drives the decision
  • Buildings where roof access must be minimized after installation

Warranty terms

  • 30 or 35-year finish warranty covering chalk, fade, and film integrity
  • 20-year weathertightness warranty available on qualifying slopes and details
  • Two-year Meridian workmanship warranty
  • Inspection required at years two, five, and every five years thereafter

At a glance

Typical lifespan
40–50 years
Best-fit building
Manufacturing, agricultural, sloped-deck buildings
Warranty
Up to 35-year finish, 20-year weathertightness
Installed cost
$12.00 – $19.00 per square foot installed, including tear-off where applicable

Cost ranges are representative of Carolinas commercial work and vary with deck condition, insulation package, and rooftop equipment density.

Standing seam metal retrofit over failed panel, 61,000 sq ft manufacturing plant
Standing seam metal retrofit over failed panel, 61,000 sq ft manufacturing plant